Quality · Testing protocols
The methods behind every spec we publish.
No claim on a Rhyfeel spec sheet exists without a documented test method behind it. Below is the matrix.
| Property | Method | Frequency |
|---|---|---|
| Water Vapor Transmission Rate (WVTR) | ASTM E96-2000 Desiccant | Every shift |
| Tensile strength (MD / CD) | ASTM D882 | Every roll |
| Tear strength | ASTM D1922 | Every batch |
| Peel strength (laminate) | ASTM D903 | Every batch |
| Hydro-head (water resistance) | AATCC 127 | Every batch |
| Pore-structure verification | SEM | Method validation |
| Defect inspection | In-line camera system | Continuous |
| Surface energy (corona) | Dyne test pen | Every shift |