Quality · Testing protocols

The methods behind every spec we publish.

No claim on a Rhyfeel spec sheet exists without a documented test method behind it. Below is the matrix.

PropertyMethodFrequency
Water Vapor Transmission Rate (WVTR) ASTM E96-2000 Desiccant Every shift
Tensile strength (MD / CD) ASTM D882 Every roll
Tear strength ASTM D1922 Every batch
Peel strength (laminate) ASTM D903 Every batch
Hydro-head (water resistance) AATCC 127 Every batch
Pore-structure verification SEM Method validation
Defect inspection In-line camera system Continuous
Surface energy (corona) Dyne test pen Every shift

Looking for a backsheet partner who ships on time?